What Guardrail Height Does EN 747-1 Require?
Short answer: EN 747-1:2024 requires an upper guardrail at least 16 cm (160 mm) above the mattress, running the full length of the open side. Zehao standard steel bunks use a 360 mm rail measured from the mattress platform — 160 mm above a 200 mm mattress — and this is reported in the SGS test.
Guardrail height is the figure buyers check most often in a tender, but it is measured two different ways. This page separates the standard minimum from our tested frame figure; both come from our published EN 747 standard page.
Direct answers
What is the minimum guardrail height under EN 747-1?
At least 16 cm (160 mm), measured from the top surface of the mattress to the top edge of the guardrail, running the full length of the open side. A thicker mattress lowers the effective height, which is why mattress thickness is written into the instruction sheet.
How does a Zehao standard bunk meet that figure?
Our standard steel bunks are built with a 360 mm guardrail measured from the mattress platform to the top of the rail. With a 200 mm mattress that leaves 160 mm above the mattress — the EN 747-1 minimum — and the figure is stated in the SGS test report.
Is 360 mm the requirement?
No. 16 cm (160 mm) above the mattress is the standard requirement; 360 mm is our measured frame dimension on standard bunks, not a regulatory number. A tender should specify the requirement and ask the supplier how the frame achieves it.
Does the figure apply to every bunk we make?
No. The 360 mm frame figure applies to standard bunk beds only. Prison / correctional, custom, OEM and project-specific builds follow the project specification, and their guardrail dimensions are stated in that specification.
Which edition should a tender name?
Name the year: EN 747-1:2024. Writing only "EN 747" leaves the edition open, and the design requirements sit in Part 1 while the test methods sit in Part 2. Our certifications page lists the standards we build to.
Measurement basis at a glance
| Figure | Value | What it means |
|---|---|---|
| EN 747-1 minimum above mattress | 16 cm (160 mm) | From top of mattress to top of guardrail, full length of open side |
| Zehao standard frame rail | 360 mm | From mattress platform to top of rail; standard bunks only |
| Standard mattress assumed | 200 mm | 360 − 200 = 160 mm above the mattress |
| Load rating (related figure) | 200 kg per berth | SGS tested, standard models; economy models 120 kg |
What a tender should write
Three lines settle it: the standard and edition year (EN 747-1:2024), the minimum guardrail height above the mattress (160 mm), and the mattress thickness the frame is designed for. Add the per-berth load rating from the weight-capacity page if the beds are for adults. See the clearance page for vertical space above the upper berth, and the guardrail-height page for the full dimension set.
Three follow-up questions
Does a thicker mattress fail compliance? It can reduce the effective height below 160 mm. State the mattress thickness in the specification and check the resulting figure against the test report.
Can I order a higher guardrail? Project-specific heights are quoted against the specification. We confirm the figure and the fixing method before production.
Where do I verify the number? In the SGS test report supplied with the quotation and on our certifications page.